A rotary evaporator (or rotavap or rotovap) uses precise engineering to effectively remove solvents from a sample using evaporation. Most rotovaps make use of a vacuum and pressure control monitor to precisely control pressure within your system, increasing evaporation efficiency. In many commercial labs, these machines need to be running ...

How Rotovap Vacuum Pump -

Aug 11, 2020 If a rotary evaporator (rotovap) is used for evaporating at 60C with a typical rotovap vacuum pump, or if a falling film still was used with a single pass, residual ethanol can remain at 3% to 8%, and decarbing may still result in 1% to … Get Details

BUCHI Rotavapor R-300 Rotary Evaporator with Controller ...

BUCHI Rotavapor™ R-300 Rotary Evaporator with Controller and V-300 Pump The R-300 meets the highest expectations in convenience and versatility. Its modular design allows extension of the Rotavapor™ R-300 to a fully integrated system where a central interface regulates each component.

Rotary Evaporator Instruction - Summit Research

Dec 14, 2016 Operating steps: Turn on rotovap, set bath temperature from 35-45c. Turn on chiller and set temperature to 0-5c. Turn on vacuum pump and set your controller to right above the cusp of the evaporation rate (generally 100mbar). Allow both coil and bath to reach temperature while vacuum is set and equalized in system to set point.

50L Rotovap Chiller and Pump - Neo Farms Proccessing ...

Description. 50L rotovap comes standard with vertical glassware and digital temperature/rotation control, while its optimized bath volume allows for rapid heat-up times. The condenser unit has specially designed glass tubes that utilize surface area extremely efficiently. That’s why our evaporators consistently deliver reliable and ...

Rotovap - Dartmouth College

Important Features of the Rotovap. 1) The vacuum pump is the source of reduced pressure in the system. 2) Spin speed and bath temperature control knobs. 3) Water bath. 4) Bump guard. 5)Cold finger. (Please do not use the rotovap if the finger is not cold. There should be excess solid dry ice in the finger.) 6)Vacuum release valve.

Rotavac Valve Tec - WebstaurantStore

inside the pump. Deposits and condensate in the pump may lead to increased temperatures even to the point of excessing the maximum permitted tempera-tures! • If there is a danger of formation of deposits in the pump chamber (check inlet and outlet of the pump), inspect the pump chambers regularly and clean if neces - sary.

How To Use Rotovap? - Lab Instruments - Henan Lanphan ...

Jul 19, 2016 How to use rotovap (when stop working)? 1.Spin the rotary knob to min, close the rotary switch; 2.Adjust the height of rotary evaporator, lift distillation flask; hold on to the flask by one hand, slowly open air valve by other hand; when vacuum degree reduce to 0, take down the flask; 3.Close the water pump; close water bath heating, close ...

Standard Operating Procedure: Rotovaps

Jun 06, 2016 ground glass joints). Prior to turning on the pump, the rotation should be turned on and the stopcock valve located at the top of the instrument should be in the closed position to ensure you do not accidentally apply vacuum to your system. Select the pump you wish to use and power it on. Then

Standard Operating Procedure: Rotovaps

Jun 06, 2016 pump as per the lab’s accepted procedure for belt drive pumps). Empty the collection reservoir into the solvent waste bottle located in the rotovap hood, remove your sample from the system and if you bumped into the bump trap remove it from the hood and subject it to the typical cleaning method employed by the lab.

Falling Film vs. Rotovaps: the fracTron solution - extraktLAB

Mar 10, 2020 Standard “Rotovap” ... D. Receipt printing, E. Feed Pump, F. Independent pumps, G. Purge Pump, H. Discharge Pump, I. UL2208, J. Pressure Sensor, K. Light Beacon. Because the fracTron 1000 is a continuous system, unlike a rotovap, disassembly is not required between runs eliminating downtime for cleaning. Clean ethanol can be pumped ...

How to use a rotovap

Mar 26, 2019 Turn on the water bath and adjust to a suitable temperature. Ensure the adapter is secured with the metal clip. Secure the flask. Ensure the flask is secure until the vacuum is turned on. Turn on the rotation to approximately two thirds of the maximum. Turn on the vacuum pump. Close the air bleed to create a vacuum in the rotary evaporator.

Rotovap Operation - Summit Research

Oct 24, 2015 Filter apparatus - cold trap - variable speed vacuum pump. Rotovap - cold trap - balloon diaphragm vacuum + controller. ... Shut off the vacuum pump for 30 seconds and put it back to 125 mbar, and slowly take it back down until the vacuum depth is stabilized so the pump may operate in hysteresis. When running say 75mbar your vacuum pump ...

Rotary Evaporator Rotovap Rotavapor Manufacturer ...

Rotary Evaporator, Rotovap, Rotavapor Manufacturer Supplier in China. If you want to find the best quality and function of rotary evaporator, our products is suitable. Capacity from 2 liter to 100 liters, fit for various of circulation heating/refrigerating pump and vacuum pump. Electric manual lift, explosion-proof device, ensure spark ...

Rotary Evaporator Fact Sheet

rotovap and the pump. Never use a liquid nitrogen to cool the trap as this can cause condensation of liquid oxygen. Empty the trap after each use. If a trap becomes clogged, immediately shut off the vacuum, disconnect the trap and e nsure it is open to atmosphere to prevent explosion. Allow the trap to thaw in a fume hood to empty. 7.

DVP Pumps - LC.40 Oil Lubricated Rotary Vane Vacuum Pump ...

The LC 40 and LC 60 pumps are suitable for continuous operation within a pressure range from 400 to 0,1 mbar (Abs.). The LC 40 and LC 60 pumps are equipped with: • Oil check valve • Exhaust mist eliminator • Automatic floating oil recovery valve • Gas ballast with manual cut-off valve • Shock mounts • Oil filter with by-pass

Rotavapor R-300

The Rotavapor R-300 meets the highest expectations of convenience and versatility in rotary evaporation. Its modular design allows the R-300 to be extended to a fully integrated system where a central interface regulates each component. Evaporating flask size: 50 – 5000 mL. Lift mechanism: Manual or automatic. Temperature range: 20 – 220 C.

Vacuum Pump V-300 Operation Manual

The [Vacuum Pump V-300] has been designed and built as an item of laboratory equipment. Its intended use is the evacuation of laboratory apparatus. This is done by means of a PTFE-diaphragm pump – with or without regulation by a vacuum controller. PTFE-diaphragm pumps are used primarily for the following applications:

Contact Us
advanced technology

High-tech Zone, Zhengzhou, China

Inquiry Online
Related Post
Leave Us Message
customer service img

We immediately communicate with you

Get Quote Online

If you have any needs or questions, please click on the consultation or leave a message, we will reply to you as soon as we receive it!

<script type="text/javascript" src="https://s9.cnzz.com/z_stat.php?id=1281099634&web_id=1281099634"></script>