2011). The rotating evaporator serves to separate a solution from its solvent so that the extract is produced with certain chemical content as desired (NuGroho and Dadang, 1999). The rotary evaporator is a tool used to extract, efficient and soft solvent evaporation. The main component is vacuum tube, controller, pumpkin evaporation, condenser and

1 L Rotary Vacuum Evaporator Instruction Manual

3) With one hand on each side of the Rotary Joint, push and pull the Rotary Joint downward until the Rotary Joint has been freed from the Driving Unit. 4) Squeeze the open end of the Rotary Joint Ring together to separate the Flask Remover and Rotary Joint Ring. 5) Re-attach the Flask Remover to the Driving Unit. How to Replace the Fuse

SCILOGEX Rotary Evaporator -

61113201 RE100-Pro Rotary Evaporator including vertical condenser, 1000ml evaporating flask NS 24/40 and 1000ml receiving flask KS 35/20, 110V, 60Hz 61110201 RE100-Pro Rotary Evaporator excluding glassware, 110V, 60Hz ... SCILOGEX_Rotary_Evaporator.pdf Author: mjwilliams Created Date:

How to use a Rotary Evaporator - University of California ...

Apr 01, 2010 The flask with the solution is placed on the rotary evaporator. The use of a bump trap prevents the solution from accidentally splashing into the condenser (and being contaminated). It is highly advisable to start with a clean bump bulb in case something bumps over after all! This would allow the experimenter to recover the solution or solid. 3.

Rotary Evaporator - Tabriz University of Medical Sciences

Author: mortaza eskandani Created Date: 9/14/2020 3:04:58 PM

Training Papers Distillation with a Rotary Evaporator

BCHI Training papers Distillation with a Rotary Evaporator 4 Advantages of the rotary evaporator (compared with static apparatus) Rotary evaporators are used for: 3 3.1 Rotavapor models 3.3.1 Glass assembly With a vacuum rotary evaporator you can carry out single-stage distilla-tion runs quickly and gently. The evaporation capacity of a ...

Section 5.13 Title: Using the Rotary Evaporator Revision ...

Brief Description of Procedure: Using a rotary evaporator to remove volatile solvents. Location: List the locations (buildings/rooms) where this procedure may be performed. For use of a PHS indicate a more precise location within the room, if appropriate, as a designated area.

Rotary Evaporator - Heidolph

evaporator. Version Alteration date 1.0 11/2019 Variants The device is available in different variants. Certain features or functions are only available in specific product variants. These variants are described in this operating manual. About this manual This operating manual is an integral part of the device described here.

Synthesis of [(R)-DTBM-SEGPHOS]NiCl2 for the ...

Jan 31, 2022 Procedure (Note 1) A. [(R)-DTBM-SEGPHOS]NiCl 2 (1). An oven--dried single-necked 25 mL ... The filtrate is concentrated on a rotary evaporator (30 C, 12 mmHg). The resulting solid is dissolved in dichloromethane (20 mL) (Note 7) and transferred to a vial (20 mL). The solution is concentrated on a rotary evaporator (30 C, 12 mmHg) and the ...

Heidolph Rotary Evaporator Industrial 20L A1C Package

Large-scale evaporator Hei-VAP Industrial Operating manual must be read before initial start-up. Please follow the safety instructions provided. Please keep for future reference. Grorotationsverdampfer Hei-VAP Industrial Betriebsanleitung vor Erstinbetriebnahme unbedingt lesen. Sicherheitshinweise beachten. Fr knftige Verwendung aufbewahren.

Phytochemical analysis antibacterial and antioxidant ...

Nov 18, 2018 Maceration) in a rotary evaporator. The temperature was set at 70C throughout the evaporation and concentration. The extracts of Soxhlet and maceration, after evaporation, were 88ml and 25ml respectively. ... The procedure was repeated for another three bacterial strains (Pseudomonas aeruginosa, Escherichia coli and Streptococcus pyogenes).

rotary evaporator distillation: operation steps of rotary ...

Procedure of operation a rotary evaporator. 1. Setup. Pour the mixture of solvent and desired compound in a round bottom flask. Best results are achieved when the flask is filled less than half full of the solution. Fill the rotovap cold traps with dry ice.

RE100-Pro LCD Digital Rotary Evaporator

Rotary Evaporator 5 supply network 2.if the device power switch is off or the plug is pulled out. • The socket for the mains cord must be easily accessible. • The voltage stated on the type plate must correspond to the mains voltage. • Socket must be earthed (protective ground contact). • Removable parts must be refitted to the appliance to

Rotary Evaporator Fact Sheet - UMass Amherst

Rotary Evaporator Fact Sheet . What are Rotary Evaporators? A rotary evaporator (also called as “rotavap” or “rotovap”) is a device used in labs for the efficient and gentle removal of solvents from samples by evaporation. The picture on the right shows what a typical rotary evaporator includes. What are Potential Hazards?

Operation Manual Rotary Evaporator - Heidolph

Rotary Evaporator Hei-VAP Precision Operating manual must be read before initial start-up. Please follow the safety instructions provided. Please keep for future reference. Original-Betriebsanleitung Rotationsverdampfer Hei-VAP Precision Betriebsanleitung vor Erstinbetriebnahme unbedingt lesen. Sicherheitshinweise bachten.e

Standard Operating Procedure - Rotary Evaporator

Rotary Evaporator Procedure 1. Load your sample into a clean round bottom flask (24/40 fit). 2. Attach the round bottom flask to the condenser. If need be, use vacuum grease located next to the rotary evaporator to create a vacuum seal between he condenser and the round bottom flask. Be sure to use a Keck clamp to secure the round

Rotary Evaporator Selection Guide - INTEK GROUP

Rotary evaporator sets usually include the rotary motor, receiving flask, heating bath, condenser, and a trap ball. You can also mix and match the rotary evaporator with different systems like ... Go through your application procedures and identify the temperature you need for the water bath you’re acquiring. At Yamato, you can choose from

SOP STANDARD OPERATING PROCEDURE - UNE

SOP STANDARD OPERATING PROCEDURE Procedure: Using a Rotary Evaporator School/Department: Science Technology/Chemistry SOP prepared by: Andrew Wallace Version: 1 Section 1 - Personal Protective Equipment 1. Lab coat 1. Eye protection 2. Proper enclosed footwear 3. Keep hair tied back 4. Fume hood 5. Gloves

The Rotary Evaporator

The Rotary Evaporator It is commonly taught in General Chemistry classes that the vapor pressure of a liquid or solid varies directly with temperature, i.e., the higher the temperature of a substance, the higher its vapor pressure. When a liquid is heated it begins to boil as the liquid turns to vapor forming

EXP 5 - Rotary Evaporator - VSIP.INFO

Theory. 2.1 Rotary Evaporator Heat and Material Balances for evaporators The basic equation for solving for the capacity of a single-effect evaporator is Eq (1) q = UA ∆T. (1) where, q , W (btu/h) = capacity of a single-effect evaporator. ∆T , K (0F) = difference in temperature between the condensing steam and the boiling liquid in the ...

Rotary Evaporation - an overview ScienceDirect Topics

Thin films of lipids are prepared by rotary evaporation from solutions in dichloromethane (CH 2 Cl 2).The lipid film is rehydrated with an aqueous solution of the reactant and/or other additives and agitated at a temperature above T c until the film has completely detached from the flask (Fig. 12.4).This results in the separation of the lipid sheets, which close on themselves to form a ...

(PDF) CHE246 - Technical Lab Report On Rotary Evaporator ...

This experiment was conducted to study the effect of temperature on the rate of evaporation of milk solution. The experiment result was taken after 10 minutes gap. The temperature was manipulated at 30⁰C, 50⁰C, 70⁰C and 90⁰C. From observation, at 30⁰C and 50⁰C, there is no presence of condensate in the receiving flask.

Rotovap Procedure and Rules - csustan.edu

Turn on the rotary spinner. 5. Turn on vacuum pump. 6. Close pressure valve on condenser unit. • Vacuum gauge should begin to rise and max out at 760 mm Hg. • If vacuum gauge maxes out at 760 mm Hg, you have a leak – fix it! 7. Lower unit into water bath. Rotovap Shutdown 1. Raise unit out of water bath. 2. Open pressure valve on ...

Rotary evaporators - Stuart Equipment

• Rotary evaporator with cold finger glass condenser for use with ice or dry ice for volatile or low boiling solvents. No cooling water required. Unique drain to empty the large 1 litre trap very easily. For each condenser pattern, there is also a plastic coating option for extra safety when using the glassware under vacuum. ...

Contact Us
advanced technology

High-tech Zone, Zhengzhou, China

Inquiry Online
Related Post
Leave Us Message
customer service img

We immediately communicate with you

Get Quote Online

If you have any needs or questions, please click on the consultation or leave a message, we will reply to you as soon as we receive it!

<script type="text/javascript" src="https://s9.cnzz.com/z_stat.php?id=1281099634&web_id=1281099634"></script>