Get a Quote

Rotary Evaporator Fact Sheet - UMass Amherst

6. Always use a cold trap in between the rotovap and the pump. Never use a liquid nitrogen to cool the trap as this can cause condensation of liquid oxygen. Empty the trap after each use. If a trap becomes clogged, immediately shut off the vacuum, disconnect the trap and e nsure it is open to atmosphere to prevent explosion. Allow the trap to ...

Home Environmental Health Safety UCI

A rotary evaporator (rotovap) is a fast and effective method of removing solvent from a flask. A rotovap removes solvent by reducing the pressure within the flask using a vacuum, rotating the sample to increase its effective surface area, and heating the solution. The steps outlined below address general laboratory safety concerns while operating a rotovap.

Ai T40 Cold Trap for Safe Vacuum Operations -

Ai T40 Cold Trap for Safe Vacuum Operations | Rotovaps.net Ai T40 Cold Trap for Safe Vacuum Operations Overview The Ai 2nd Gen -40C/F T40 cold traps now all come UL/CSA certified, standard. They have a much smaller footprint, but at the same time, offering you the same cooling power, 1.5X reservoir and 1.6X trap capacity.

How to Operate a Rotovap? - Lab Instruments - Henan ...

Apr 26, 2017 Adjust vacuum as needed. 14. Once the sample has stabilized, lower the flask into the water bath. 15. Continue to rotovap as long as necessary. 16. If you need to break the vacuum to the pump to discard solvent from the trap or add ice to the dry ice trap, open the valve and leave the vacuum pump running.

The Role that a Cold Trap Plays in a Rotary ... - Rotovap

Aug 21, 2019 It is a device placed between a vacuum vessel and a pump for adsorbing gas or trapping oil vapor. In rotary evaporator equipment, cold trap plays a very important role. It is cylindrical and has two flanges on the upper and lower sides. The lead gasket is lined with a lead gasket and is connected to the vacuum pump and the suction container.

Cold Traps For Vacuum Pumps Shop BVV

BVV carries a wide selection of cold traps to protect your pumps from condensable vapors. Shop cold traps for vacuum pumps, dry ice traps, and more! Call Us 331.281.0154 Financing

10l rotovap - Lab Instrument Manufacturer

Connect chiller to condenser and set to 0C (32F). Always fill a rotovap condenser from the top down (chiller output to top of condenser, chiller input to bottom of condenser). Connect vacuum pump to cold trap and connect cold trap to vacuum port on …

20l Rotary Evaporator with Vacuum Pump and Chiller - Lab ...

Connect vacuum pump to cold trap and connect cold trap to vacuum port on rotovap. Turn on heat bath and set to 40C (113F). Once heat bath, chiller and cold trap have reached desired temperatures, turn on rotovap motor and set speed to approximately 100 RPM (does not have to be precise). Keep in mind, higher RPM’s will increase evaporation ...

Rotary Traps Fisher Scientific

DWK Life Sciences Kimble™ Kontes™ Self Washing with Square Joint Bead Rotary Evaporator Trap. This trap is designed to eliminate hold-up common to the round style of rotary evaporator traps. Available in 100mL or 250mL capacities, with 14/20 or 24/40 bottom taper joints and 24/40 top taper joints. Promotions are available.

Rotary Evaporators Rotovaps Molecular Gastronomy

Feb 15, 2021 The rotovap is operated under a vacuum to lower a compound’s boiling point whilst the sample is heated at the same time. When the pressure of a liquid decreases, the boiling point reduces and the solvent can be vaporized at a lower temperature than their standard boiling point. ... How Ecodyst Evaporators Differ from Cold Traps for Vacuum ...

Need a cold trap? - Chemistry Stack Exchange

Ideally you should have pump attached to dry ice/acetone trap followed by a cold water condenser (from the rotovap). There are several reasons to have a cold trap. Protection of the pump is one of them. The other reason is that a pump can maintain deep vacuum OR pump large volume of material, but not both. By capturing solvents in the trap you ...

Rotovap - Dartmouth College

Important Features of the Rotovap 1) The vacuum pump is the source of reduced pressure in the system. 2) Spin speed and bath temperature control knobs. 3) Water bath. 4) Bump guard. 5)Cold finger. (Please do not use the rotovap if the finger is not cold. There should be excess solid dry ice in the finger.) 6)Vacuum release valve.

How Ecodyst Evaporators Differ from Cold Traps for Vacuum ...

Jan 13, 2022 Cold traps are generally placed between the vacuum pump and the rotovap to safeguard the pump from any additional contamination. Cold traps are usually a critical element of standard rotovaps as they catch any vapors that pass through the condenser. Cold traps are lined with lead and are connected to both the suction container and the vacuum ...

Standard Operating Procedure: Rotovaps

Jun 06, 2016 slowly apply vacuum to your rotovap system by regulating the stopcock valve at the top of the rotovap. If the flask contents bubble vigorously, you should cease applying direct vacuum to prevent bumping up ... bumped into the bump trap remove it from the hood and subject it to the typical cleaning method employed by the lab.

Rotary Evaporator Accessory Options Blog

Mar 02, 2021 Rotary Evaporator Accessory Options. By Aimee O'Driscoll, 02 March 2021. A rotovap setup can be quite complex. You have your basic components including the rotary evaporator and glassware, chiller, and vacuum pump and controller, but there are also a number of accessories that can help optimize your process. We covered the core components of a ...

AI Rotovaps for Solvent Recovery Fractional Distillation ...

Nov 04, 2015 Benefits of the Rotovap vs. Cold trap? A.Rotovap offers much closer control of evaporation of liquid phase materials due to smaller volume thus finer vacuum control. B.HOWEVER, vacuum oven’s deeper vacuum capabilities allow material to be degassed recollected at lower temperatures. Do I need a vacuum pump? Yes, but not just any vacuum …

How to use a rotary evaporator -

Nov 09, 2018 Most labs use a simple water aspirator vacuum on their rotavaps, so a rotavap cannot be used for air and water-sensitive materials unless special precautions are taken i.e. additional traps are used. In the lab, the house vacuum line, a circulation bath or a membrane pump are used as source for the vacuum (40-50 torr).

Rotovap Operation - Summit Research

Oct 24, 2015 Filter apparatus - cold trap - variable speed vacuum pump. Rotovap - cold trap - balloon diaphragm vacuum + controller. We suggest these components because they work exceptionally, in fact compared to YouTube videos you will never find a better performing glassware set. The Wilmad lab glass 90 mm filter apparatus.

Rotovap Startup - csustan.edu

Rotovap Startup 1. Turn on the chiller 5-10 minutes prior to evaporation. ... C. Pay attention to the bump trap as you lower the unit. • Make sure you do not press the trap against the water bath – SNAP! ... • This will result in leaks, poor vacuum, and an inoperable rotovap. C. Do not continually pump on a collection flask which contains ...

Rotavapor R-300

The Rotavapor R-300 meets the highest expectations of convenience and versatility in rotary evaporation. Its modular design allows the R-300 to be extended to a fully integrated system where a central interface regulates each component. Evaporating flask size: 50 – 5000 mL. Lift mechanism: Manual or automatic. Temperature range: 20 – 220 C.

Rotovap and Lyophilization - Adams Chittenden Scientific ...

The rotovap cleaner assists you in cleaning out the gunk that accumulates in the vapor duct and head of your rotary evaporator. With the rotation stopped, connect the cleaner to the vapor duct with the stopcock closed. Add solvent to the funnel, turn on the vacuum, then open the stopcock. The solvent will burst through the vapor duct into the ...

Rotovap - Dartmouth College

The rotovap should be turned on and the trap cooled. If this is not the case, ask your TA for assistance. 1. Attach your flask to the bump guard of the rotovap using a Keck clip. ... Close the stopcock (marker #1, right photo) to create a vacuum inside the rotovap. Stopcock #2 (right photo) should not need adjustment. Stopcock #2 should be open ...

USA Lab 2L Rotovap Bump Trap Adapter 24/40 - USA Lab

The USA Lab 2L bump trap is a convenient add on for your 2L rotovap. This product is designed to catch any splash back from your rotovap. For Technical Support, Questions, or Other Issues Please Email or Call Us! Other top rated products Rotovap Dome Cover - 20L, 50L (2) USA Lab 1 5 Micron... (1) USA Lab 8MM Rubber Vacuum Hose... (2)

Vacuum Traps- Chemglass Life Sciences

vacuum traps, solvent vapor, ptfe stopcocks, plastic coated . cg-4523 vacuum traps, solvent vapor, chem-drain, plastic coated *in-stock. cg-4525 vacuum traps, dual chambers . cg-4527 vacuum traps, removable arms . cg-4529 vacuum traps . cg-4531 vacuum traps . cg-4532 vacuum traps, rodaviss threaded joint .

Contact Us
advanced technology

High-tech Zone, Zhengzhou, China

Inquiry Online
Related Post
Leave Us Message
customer service img

We immediately communicate with you

Get Quote Online

If you have any needs or questions, please click on the consultation or leave a message, we will reply to you as soon as we receive it!

<script type="text/javascript" src="https://s9.cnzz.com/z_stat.php?id=1281099634&web_id=1281099634"></script>